1734-ib8s ms blinking. $590. 1734-ib8s ms blinking

 
 $5901734-ib8s ms blinking  Appendix A

If you need a specific series relating to 1734-IB8S, we probably have it. User Manual. 131Buy 1734-IB8S / 1734-IB8S Allen Bradley Point Guard I/O Module from Distributor Santa Clara Systems. the pulse period (Y) is typically 144 ms. Flashing green NS, it's online with no connections in established state, verify network and module config. 44 W 3. FS. Allen-Bradley 1734-IB8S POINT Digital Input Module 24VDC 8-Ch Sink Safety, Ser B:. 03 postage. This module is a POINT Guard IO Safety. Digital I/O Modules; POINT Digital DC Input Modules: 24V Dc 8 Channel Sink Input Module: Supporting Documentation and Downloads. Description – potential anomaly that exists with Allen-Bradley POINT Guard I/O 1734-IB8S/B and 1734-IB8SK/B modules that may exhibit an intermittent connection fault. 00. Find more technical documentation for this product in the Technical Documentation Center . Dual-channel Equivalent. Recommended Action - Check the field wiring and verify your. TYPE. 1734 Ib8s Wiring Diagram. The Allen-Bradley 1734-IE2V is a POINT I/O Analog Input Module. If you need a specific series relating to 1734-OB8S, we probably have it. Stock. PUBLICATION NUMBER. 1734-IN016. (2) If you are using digital POINT Guard I/O modules with the analog POINT Guard I/O module, you must update the Add-on Profiles to version 2. 1734-IB8S, 1734-OB8S, 1734-IE4S – Technical Specifications Attribute 1734-IB8S 1734-OB8S 1734-IE4S POINTBus POINTBus current, max 175 mA 190 mA 110 mA @ 5V Power dissipation, max 2. Chapter 4. Order Today!4 Rockwell Automation Publication 5069-TD002B-EN-P - July 2016 CompactLogix 5380 Controllers Specifications Weight, approx 0. For the 1734-IB8S module, the pulse width (X) is typically 525 s; the pulse period (Y) is typically 144 ms. 1 Ethernet Module (Resolver) The problem is just in a 1734-IB8S, sometimes the machine stops, operator push the reset button and continue working, but sometimes the adapter goes to fault and we need to shutdown the machine. Configure the Module in a GuardLogix Controller 17. 4 W; Terminal Base Units: 1734-TB, 1734-TOP, 1734-TOP3. Join Now! We have updated our data protection policies based on new GDPR act. I have setup the AENTR with the proper IP address and chassis size (4) in the I/O tree and it matches what is in the web browser. 95 MB. Network Status. 2 msPulse Test Output Type: Current Sourcing; Number of Sources (T0, T1M, T2, T3M): 4; Test Output Current (Each Output Point): 0. POINT I/O 8 Point Digital Output Module. 00. 52. To find an answer using a previous Answer ID, click here. Whether you are using AOPs for these modules or not will depend on your network architecture and whether or not you have these modules added to the I/O Configuration in RSLogix 5000/Logix Designer. 288. 8 Volts DC. 5. 4 W; Terminal Base Units: 1734-TB, 1734-TOP, 1734-TOP3. 12 months warranty. Flashing red - A fault in the partner input circuit of a dual-input configuration has been detected. redd. 3 mA; PointBus Current: 175 mA; Maximum Power Dissipation: 1. 5 BTU/hr Isolation voltage 50V (continuous), Basic Insulation Type between field side and system 1734-IB8S, 1734-OB8S, 1734-IE4S – Technical Specifications Attribute 1734-IB8S 1734-OB8S 1734-IE4S POINTBus POINTBus current, max 175 mA 190 mA 110 mA @ 5V Power dissipation, max 2. View and Download Allen-Bradley 1734-IB2 installation instructions manual online. One thing we have identified is random comm faults. Some need a power cycle to clear. Search Partnumber : Match&Start with "1734 IB8S " Total : 336 ( 1/17 Page) High Performance Interconnects ( HPI ); 8P,HPI 2. 2. Allen-Bradley 1734-IB8S POINT Digital Input Module 24VDC 8-Ch Sink Safety, Ser B:. Allen Bradley POINT Guard IO Safety Modules 1734-IB8S, 1734-OB8S, 1734-IE4S . POINT Guard I/O Safety Modules. Please login to see accurate availability. Installation Instructions. I was using an ENBT in the main rack and remote rack for remote IO comm. Please call or email us your request. )Allen-Bradley 1734-IB8 POINT Digital DC Input Module 24V DC 8 Channel Sink, Series C 10612598308573 UPP Ser C. PUBLICATION NUMBER. Reviews (0)1734-IB8SK PLCs/Machine Control from ALLEN BRADLEY In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - POINT GUARD I/O SAFETY MODULE,** CONFORMAL COATED**, 8 SAFETY DIGITAL INPUT, SIL 3, PLE, 24 V DC. If the item is not as described, you will have a full refund including all. 1734) Safety Digital Input Module 8qty 24V DC Sinking (PNP) type 4qty 24V DC 55°C max-20°C min 85°C max-40°C min 95%RH REFERENCES Installation Guide: - User Manual: - Manufacturer Datasheet: - Manufacturer Catalogue & Product Selection:-Supplier Declaration of Conformity:-IECEx Certificate -1734-IB8S / OB8S getting 16#0203 fault. 7 A. 2 W Thermal dissipation 8. 9393. The Compact GuardL ogix 5380 and GuardLogix 5580 controllers must use firmware revision 32. View online or download PDF (11 MB) Allen-Bradley 1734-IB8S, 1734-OBV2S, 1734-IE4S, 1734-OB8S User manual • 1734-IB8S, 1734-OBV2S, 1734-IE4S, 1734-OB8S PDF manual download and more Allen-Bradley online manuals. redrabbitconsultants17 (1,097) 100%. None. Flashing green NS, it's online with no connections in established state, verify network and module config. The 1734. It has 2 single-ended, non-isolated, voltage Inputs and a Delta Sigma Conversion Type with a Power Dissipation of 0. 10. Lifecycle status: ACTIVE. 12 mm. Read this section for examples of wiring by application. Allen-Bradley 1734-OB8S POINT I/O Output Module with 8-Channel Safety Sourcing, 1A max, Series A 10612598350640 SSP Ser A2 Rockwell Automation Publication 1734-IN052H-EN-E - September 2022 POINT I/O Source Input Modules Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. Pull up on the RTB removal handle to remove the terminal block. Input delay time, on to off: 0. Installation Instructions. net - Interactive Q & A You are not registered yet. 7. 4 W; Terminal Base Units: 1734-TB, 1734-TOP, 1734-TOP3. It's a bit of a placebo but surprisingly, solves a lot of problems. We Offer Emergency Shipping and Drop-Ship Services. Allen-Bradley 1734-IB8S PLC Input/output Module. Product Notice 2022-05-001 - Allen-Bradley POINT Guard I/O 1734-IB8S/B, 1734-IB8SK/B Intermittent Connection Fault. 该模块是一个. Flashing red since commissioning. User Manual. PLC Department does not store payment information. Configuration Ownership states Not Owned and Status. General Specifications - 5094-IA16, 5094-IA16XTBuy 1734-IB8 / 1734-IB8 Allen Bradley 8-Channel 24V Dc Sink Input Module from Distributor Santa Clara Systems. Try our online PLC Simulator-. Safety controllers control the safety outputs. 1734-ib8s wiring examples. Configuration Ownership states Not Owned and Status still. Project. The 1734-IB8S is a POINT Guard I/O Safety Module by Allen-Bradley and Rockwell Automation. Brand: Allen-Bradley | Category: Control Unit | Size: 12. DC. 02. 3 mA/5 mA; Maximum Off-State Current: 1. To find an answer using a previous Answer ID, click here. Purchase Allen-Bradley 1734-IB8S digital input safety modules from Industrial Automation Co today. Recommended Action. When the system is 1: Power Supply. Test Output 1. Check part details, parametric & specs updated 12 NOV 2023 and download pdf datasheet from datasheets. 2 ms max; On-State Current Min/Max: 3. If you’re using a safety relay for solenoid output then odds are you just need the one. 02 W 2. 1734-UM013. Project. The 1734. Please call or email us your request. Si se produce la anomalía, el resultado será el siguiente: • El modo de fallo del módulo 16#0010 o el estado del módulo no permite que el objeto realice el servicio solicitado • Se agotó el tiempo de conexión del fallo del módulo 16#0203I have a 1734-aentr com module, 3 standard I/O cards, a power supply module and then 4 safety I/O cards. Reaction Time: 16. 8 Channel Sfty Sinking Inp Mod PN-25132. 5500. 10. Find all available product literature for this product in the Literature Library results . txt) or read online for free. Flashing red MS it's in recoverable fault, reconfigure the module. 8VDC); Input Delay Time, On to Off: 16. RESOURCE. 2 ms max; On-State Current Min/Max: 3. Installation Instructions. Check part details, parametric & specs updated 17 NOV 2023 and download pdf datasheet from datasheets. PUBLICATION NUMBER. Tested and 2-Year Warranty. 3 mA/5 mA; Maximum Off-State Current: 1. None. Wall mounting/direct mounting. Brand: Allen-Bradley | Category: I/O Systems | Size: 9. 34 BTU/hrr 10. How to fix 1734-AENTR pointbus status blinking red 6 1734-AENT POINT I/O. 752. Installation Instructions. 201 and successfully disable it so static IP can be set to EPROM. Free shipping. e. 5 ms hardware + (0…65 ms selectable); On-State Current Min/Max: 2 mA/5 mA; Maximum Off. However when I changed the configuration for pulse test it no longer works; Input Config; Type: Single. Installation Instructions. This product was certified with the above certifications as of 2023-11-08. it) submitted 1 year ago by Capital-Ant-1303. Installation Instructions. Allen-Bradley 1734-IB8S Point I/O 8-Point Combination Module. Alternatively, you can use the POINT I/O one-piece mounting base (catalog numbers 1734-TOP, 1734-TOPS, 1734-TOP3, or 1734-TOP3S). 8 Safety-Rated Sink Inputs 24V DC (11VDC 10612598350619 UPP Ser B 1. 004 or later for the modules to be compatible with version 18 or later of. In module properties ->safety tab, click reset ownership, the NS light comes on but MS stays blinking red. 5 milliAmps at 40 degrees Celsius and 11…28. I've managed to source a few spares, but they are all series A cards. ni / w 2( mc / W8,0 ). The 1734-IB8S is a POINT Guard I/O safety Discrete Input Module. Pin on playing with carsPulley dyno tronic gearbox supercharger 0t 30tfsi tfsi crank further ecu dsg Next-gen audi 3. If the. WARNING: For 1734-RTBS and 1734-RTB3S, to latch and unlatch the wire, insert a bladed screwdriver (catalog number 1492-N90 – 3 mm diameter blade) into the opening at approximately 73° (blade surface is parallel with top surface of the opening) and push up gently. POINT I/O Input Modules 5 Publication 1734-IN051F-EN-E - August 2005 Identify the Components Use the figure to identify the external features of the module. Manufacturer: Allen-Bradley. 1734-UM013. AB Safety Input Module 1734-IB8S Loses Configuration LIVE PLC Questions And Answers AB Safety Input Module 1734-IB8S Loses Configuration - PLCS. Who Should Use this Manual. This product was certified with the above certifications as of 2023-11-09. Buy 1734-IB8S / 1734-IB8S Allen Bradley Point Guard I/O Module from Distributor Santa Clara Systems. Electrical, Mechanical Products, Commercial, Industrial Items. Pre-Owned. Products sold before or after this date might carry different certifications. 1734-IN016. 3 mA/5 mA; Maximum Off-State Current: 1. User Manual. The Allen-Bradley 1734-IB8S is a POINT Guard I/O Safety Discrete Input module. MS light blinking red. 800. User Manual. 19 MB. 2 ms max; On-State Current Min/Max: 3. Find all available product literature for this product in the Literature Library results . SOLVE. plc-mall. allen bradley. Type of voltage (input voltage) DC. Get 1734-IB8S 8 CHANNEL SAFETY SINKING INPUT at wholesale prices at Westburne Electrical Distributor - your electrical distributor. welcome to contact us when you need the products, we can response in 12 hours. Products sold before or after this date might carry different certifications. We Offer Emergency Shipping and Drop-Ship Services. 168. The 5069-IB8SK module offers the same functionality as the 5069-IB8S module but also has conformal coating to help protect it in harsh environments. 2 msPulse Test Output Type: Current Sourcing; Number of Sources (T0, T1M, T2, T3M): 4; Test Output Current (Each Output Point): 0. EDIT: Studio 5000 v26 EDIT: only slot 2 has the triangle Publication 1734-IN510B-EN-P - August 2000 Wiring Diagrams Specifications General specifications - These specifications are shared by all components of the 1734 POINT I/O system. The RIO handles emergency stop circuits, light curtains, etc. Reaction Time: 16. 5 BTU/hr Isolation voltage 50V (continuous), Basic Insulation Type between field side and. Expert Repair Service. 3. Jdeloz828. 02 W 2. PUBLICATION NUMBER. Si se produce la anomalía, el resultado será el siguiente: • El modo de fallo del módulo 16#0010 o el estado del módulo no permite que el objeto realice el servicio solicitado • Se agotó el tiempo de conexión del fallo del módulo 16#0203 I have a 1734-aentr com module, 3 standard I/O cards, a power supply module and then 4 safety I/O cards. Installation Instructions. I/O Module, Safety, 8 Point Input, Compatible with Terminal Bases with 8 Terminations. Rango de voltaje 1734-IB8S 143 Especificación de voltaje de entrada en estado desactivado 143 Rango de temperatura 1734-IB8S 144 Rango de temperatura 1734-OB8S 145 Especificaciones de voltaje de aislamiento 146 Código de temp. Flashing red MS it's in recoverable fault, reconfigure the module. $ 260. Reaction Time: 16. Allen-Bradley 1734-IB8 POINT Digital DC Input Module 24V DC 8 Channel Sink. Number of outputs will depend. Affected 1734-IB8S modules must be replaced. 75 Watts at 28. Find all available product literature for this product in the Literature Library results . point i/o input modules series C. Rockwell Automation Publication 1756-PM014N-EN-P - March 2022 Supersedes Publication 1756-PM014M-EN-P - September 2020 Programming Manual Original Instructions Logix 5000 ControllersIntervallo di tensione del 1734-IB8S 141 Specifiche tensione di ingresso in stato Off 141 Gamma di temperatura del 1734-IB8S 142 Gamma di temperatura del 1734-OB8S 143 Specifiche della tensione di isolamento 144 Codice di temperatura nordamericano 144 Gamma temperature di funzionamento 145 Specifiche dell’immunità dalle frequenze radio. It has been designed as part of the Allen-Bradley 1734 POINT Guard I/O module series. I have a 1734-aentr com module, 3 standard I/O cards, a power supply module and then 4 safety I/O cards. Alternates Common Typos 1734-18851734-188S1734-18B51734-18BS1734-1B851734-1B8S1734-1BB51734-1BBS1734-I8851734-I88S1734-I8B51734-I8BS1734-IB851734-IBB51734-IBBS1734-L8851734-L88S1734-L8B51734-L8BS1734-The 1734-OB8S can be purchased online and your order will ship today. Spec Sheet. Wiring Examples. DetailsThe 1734-IB8S and -OB8S Series A modules use an older AOP (v2. ) It has a dual-channel mode that will control any redundancy using 2 output signals. Installation Instructions. TYPE. TYPE. If you’re using the STO of a VFD that requires a dual channel input you’ll need to utilize 2 outputs. 10 Publication 1734-UM013A-EN-P - February 2009 Chapter 1 POINT Guard I/O Overview Before You Begin Always observe the following guidelines when using a module, noting that in1734-IB8S, 1734-OB8S, 1734-IE4S – Technical Specifications Attribute 1734-IB8S 1734-OB8S 1734-IE4S POINTBus POINTBus current, max 175 mA 190 mA 110 mA @ 5V Power dissipation, max 2. Is there a limitation of length for the pulse test generated by the 1734-IB8S: I want to wire many switches (explosion vents) which are far apart in series to a single input and I was wondering if the pulse test (say T0. 32 BTU/hr 7. This module is typically used in applications that perform safety. If you need a specific 1734-IB8S series, then we probably have it. We Offer Emergency Shipping and Drop-Ship Services. Rockwell Automation Publication 1734-UM013J-EN-P - July 2014. User Manual. 0 . Changes throughout this revision are marked by change bars, as shown to the right of. ni / w 3( mc / W 2,1 otazzilitu eneiv S4EI. POINT I/O 8 Point Digital Output Module. 1734-IN016. Find Product Drawings. Références 1734-IB8S, 1734-OB8S Notice d’installation et Manuel utilisateur. radwell 2-year warranty included. 3 mA/5 mA; Maximum Off-State Current: 1. Solid red. If problem persists, replace the module. Appendix A. 3 mA/5 mA; Maximum Off-State Current: 1. 004 or later for the modules to be compatible with version 18 or later of. Make sure this fits by entering your model number. If an affected 1734-IB8S module is placed in a running system, the modules will work correctly. DIGITAL INPUT SAFETY MODULE, 8 POINT, SAFETY SINKING, 8. 3 mA/5 mA; Maximum Off-State Current: 1. Request repair. This since the E-Stop is connected to T0 and T1m. 3 mA;. User Manual. 1734-IN016. Flashing red The module has detected a recoverable fault. 1734-IN016. The module detected an. net - Interactive Q & A You are not registered yet. 5 BTU/hr Isolation voltage 50V (continuous), Basic Insulation Type between field side and system Guard I/O 1734-IB8S/B y 1734-IB8SK/B, que pueden presentar un fallo de conexión intermitente. Find all available product literature for this product in the Literature Library results . The 1734-OB8E is a protected discrete input module that is part of Allen-Bradley’s POINT IO product family. Please. 7. it) submitted 1 year ago by Capital-Ant-1303. The issue I am having is that the 1st and 3rd (Slot 4 & 6) safety I/O cards are losing their configuration which results in an E-Stop being triggered. 1734 wiring diagram point manual rockwell automation fpd modules analog user onesource mfg wires underground. Installation Instructions. 2 Rockwell Automation Publication 1734-IN033F-EN-E - September 2022 POINT I/O 8 Channel High Density Current Input Module Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or. When the external input contact is closed, a test pulse is output from the test output terminal to diagnose the. User Manual. Download it for free from Rockwell. 1734 vhsc24 wiring. Catalog Number 1734-IB8S 1734-OB8S 1734-IE4S 1734-OBV2S Description 24V DC Input Module 24V DC Solid-State Output Module Analog Input Module 24V DC Solid-State Output Module I/O Channel Isolation No Channel - Channel Isolation No Channel - Channel Isolation No Channel - Channel Isolation1734-IB8S. Flag. Popular Brands. Recommended Action. Add-On Profile for 1734-AENT and 1734-AENTR Series C. 97 x 98. Find Product Drawings Product. Find all available product literature for this product in the Literature Library results . 8 Channel Sfty Sinking Inp Mod PN-25132. 1734-IB8S. Installation Instructions. THINK. 5 ms hardware + (065 ms selectable) Current, on-state input, min: 2 mA; Current, on-state input, max. Installation Instructions. About the Module The 1734 sink input modules are available in 2 input, 4 input, and 8 input. The 1734-IB8S module is monitoring the input from the SafeZone laser scanner control. SKU: 1734-IB8S Category: POINT Guard I/O Modules. 1734-IB8S, 1734-OB8S, 1734-IE4S – Technical Specifications Attribute 1734-IB8S 1734-OB8S 1734-IE4S POINTBus POINTBus current, max 175 mA 190 mA 110 mA @ 5V Power dissipation, max 2. Price and delivery upon quote request. 1734-IB8S Connection Faults. AB Safety Input Module 1734-IB8S Loses Configuration LIVE PLC Questions And Answers AB Safety Input Module 1734-IB8S Loses Configuration - PLCS. 0…7. com web wiring with wire end ferrule wire size range n. A potential anomaly that exists with Allen-Bradley POINT Guard I/O 1734-IB8S/B and 1734-IB8SK/B modules that may exhibit an intermittent connection fault. 7 A Max;Publication 1734-IN051I-EN-E - June 2015 Environment and Enclosure Preventing Electrostatic Discharge ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. Products sold before or after this date might carry different certifications. 1734-OB8 PLCs/Machine Control from ALLEN BRADLEY In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - I/O DIGITAL OUTPUT MODULE, 5 VDC, 75 MA, OUTPUT: 1 AMP, 24 VDC, 24 VA, 8 POINT. Request for Repair. PUBLICATION NUMBER. The SafeZone laser scanner control provides two PNP outputs that are turned off when an object interrupts its field of view. Installation Instructions. If the anomaly occurs, the result will be as follows: Module fault 16#0010 mode or state of module does not allow object to perform requested service. Reaction Time: 16. Table of Contents. 7 A Max;Rockwell Automation 1734-IE4S POINT Guard I/O Safety Modules User Manual User Manual • Configure the test outputs • Rockwell Automation Equipment. In the Name field of the New Module dialog box, type a °Â 04 C °Â 02- ). 2 ms; Output type : Current sourcing; Number of sources (T0, T1M, T2, T3M) : 4; Test output current (each output point) : 0. Rockwell Automation's 1734-IB8S is a point guard i/o safety modules 8 safety. com +91 9911104090. Allen-Bradley 1734-IB8S Manual Online: Module. 2 ms max; On-State Current Min/Max: 3. We guarantee the equipment in all the services offered for 12 months. Ships from and sold by GOYGOY. 4 W; Terminal Base Units: 1734-TB, 1734-TOP, 1734-TOP3. (10VDC - 28. Rockwell Automation Publication 1734-UM001E-EN-P - July 2013 Preface Purpose of This Manual This manual describes how to install, configure, and troubleshoot your POINT I/O modules. 2022 honda insight trim levels2022 honda insight buyer's guide: reviews, specs, comparisons 2022 honda insight review engine2022 honda insight:. Never work Test: tried power cycle yet still flashing red. Reference: 2022-05-001 . 14. Input delay time, on to off 0. pl. 7 A Max;Description: Allen-Bradley, Rockwell Automation | 1734-IB8S/B | Digital Input Module 24VDC 8-Ch Sink Safety POINT Digital DC Input Module 24V DC 8-Ch Sink Safety-Rated. 5 ms hardware + (065 ms selectable) Current, on-state input, min: 2 mA; Current, on-state input, max: 5 mA;. 3 mA; PointBus Current: 175 mA; Maximum Power Dissipation: 1. 5962 Welcome! The 5069-IB8SK module offers the same functionality as the 5069-IB8S module but also has conformal coating to help protect it in harsh environments. This module features Eight (8) 1 group of 8, non-isolated, sourcing, output channels. Rockwell Automation's 1734-IB8 is a digital dc input modules. Download the user manual in PDF format from this link. Installation Instructions. Please call or email us with your request. Indicator. 24V Dc 8 Channel Sink Input Module. POINT I/O Terminal Bases: Selection, Compatibility & Internal Wiring. Hi all, I searched for the information but couldn't find anything in the 1734-IB8S user manual. RESOURCE. Plug-in connection. 693 lb) Dimensions (HxWxD), approx 143. 2 Rockwell Automation Publication 1734-IN056K-EN-E - September 2022 POINT I/O Protected Output Module Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain this product. £233. Please review the product label to check for the certifications your specific product carries. 18 Publication 1734-UM013A-EN-P - February 2009 Safety Functions Chapter 2 . 1734-IB8S $ 554. RESOURCE. With one to eight channel density modules, including a self-configuring discrete module, the modularity of POINT I/O minimizes. Products sold before or after this date might carry different certifications. 1734-IB8. Description. 4 W; Terminal Base Units: 1734-TB, 1734-TOP, 1734-TOP3. in the tools and supplies, misc products category. + £22. Lifecycle status: ACTIVE Find a Distributor Learn how to avoid the risks of unauthorized and counterfeit. Width. Safety output is on. Installation Instructions. Input Delay Time, On to Off: 16. Point i/o 2 current and 2 voltage input analog modules (22 pages) Control Unit Allen-Bradley POINT I/O 1734-ADN Installation Instructions Manual. 5500. Comm link with EN2TR rack1 config: 1X 1734-AENTR/C7X analog IE4S/A 7X IB8S /B Rockwell support is off duty on weekends so I figure why not here. 99 $ 1,449. Off.